{"id":3324,"date":"2019-06-03T13:46:47","date_gmt":"2019-06-03T11:46:47","guid":{"rendered":"https:\/\/www.gino-ag.com\/?page_id=3324"},"modified":"2025-02-04T14:39:38","modified_gmt":"2025-02-04T13:39:38","slug":"discover-surge-protection-gino-ag","status":"publish","type":"page","link":"https:\/\/gino-ag.xtek.site\/en\/products\/discover-surge-protection-gino-ag\/","title":{"rendered":"Surge suppressor"},"content":{"rendered":"<div id=\"pl-3324\"  class=\"panel-layout\" ><div id=\"pg-3324-0\"  class=\"panel-grid panel-has-style\" ><div class=\"sidebar-row panel-row-style panel-row-style-for-3324-0\" ><div id=\"pgc-3324-0-0\"  class=\"panel-grid-cell\" ><div id=\"panel-3324-0-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child\" data-index=\"0\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-editor so-widget-sow-editor-base\"\n\t\t\t\n\t\t>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<h2>Transient overvoltage protection with ZORC modules<\/h2>\n<p>GINO AG is the exclusive distributor of ZORC modules in Germany. With the modules, we guarantee you safe surge protection.<\/p>\n<p>Protect your valuable electronic equipment with our ZORC modules for surge protection. Contact us today for more information and to find the optimal solution for your individual needs. Rely on our proven products to protect your electronics from surges and minimize downtime.<\/p>\n<h3>ZORC: Zinc - Oxide - Resistor - Capacitor<\/h3>\n<p>ZORC is a unique surge arrester designed to protect motors, transformers and generators from steep wave fronts such as voltage spikes, momentary excursions and other voltage fluctuations or disturbances caused by switching operations.<\/p>\n<\/div>\n<\/div><\/div><div id=\"panel-3324-0-0-1\" class=\"so-panel widget widget_block\" data-index=\"1\" ><div style=\"background-color: white; border: 4px solid yellow; border-radius: 10px; padding: 20px;\">\n<h3 style=\"margin-bottom: 10px;\">Are you interested in our surge protection?<\/h3>\n<p style=\"margin-bottom: 20px;\">Get in touch with us. We will prepare a customized offer for you.<\/p>\n<p>  <a href=\"https:\/\/www.gino-ag.com\/de\/kontakt\/kontakt\/\" style=\"background-color: black; color: white; padding: 10px 20px; text-decoration: none; border-radius: 5px;\">Contact us<\/a>\n<\/div>\n<\/div><div id=\"panel-3324-0-0-2\" class=\"so-panel widget widget_sow-editor\" data-index=\"2\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-editor so-widget-sow-editor-base\"\n\t\t\t\n\t\t>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<h2 aria-level=\"2\">Key features of ZORC modules for surge protection<\/h2>\n<ul>\n<li aria-level=\"2\">Financial savings by avoiding production downtime caused by insulation damage in motors and transformers<\/li>\n<li aria-level=\"2\">Not only protects motors, generators and transformers, but also extends their service life<\/li>\n<li aria-level=\"2\">Eliminates frequently occurring high and low pulses and interference factors associated with vacuum interrupters and other switchgear<\/li>\n<li aria-level=\"2\">Standard and intrinsically safe models available<\/li>\n<li aria-level=\"2\">Available as three-phase or single-phase models<\/li>\n<\/ul>\n<\/div>\n<\/div><\/div><div id=\"panel-3324-0-0-3\" class=\"so-panel widget widget_widget_accordions\" data-index=\"3\"><h3 class=\"widget-title\">Good to know<\/h3><div id=\"accordions-10209\" class=\"accordions-10209 accordions\" data-accordions={&quot;lazyLoad&quot;:true,&quot;id&quot;:&quot;10209&quot;,&quot;event&quot;:&quot;click&quot;,&quot;collapsible&quot;:&quot;true&quot;,&quot;heightStyle&quot;:&quot;content&quot;,&quot;animateStyle&quot;:&quot;swing&quot;,&quot;animateDelay&quot;:1000,&quot;navigation&quot;:true,&quot;active&quot;:999,&quot;expandedOther&quot;:&quot;no&quot;}>\r\n                <div id=\"accordions-lazy-10209\" class=\"accordions-lazy\" accordionsId=\"10209\">\r\n                    <\/div>\r\n\r\n    <div class=\"items\"  style=\"display:none\" >\r\n    \r\n            <div post_id=\"10209\" itemcount=\"0\"  header_id=\"header-1726481344806\" id=\"header-1726481344806\" style=\"\" class=\"accordions-head head1726481344806 border-none\" toggle-text=\"\" main-text=\"What is surge protection?\">\r\n                                    <span id=\"accordion-icons-1726481344806\" class=\"accordion-icons\">\r\n                        <span class=\"accordion-icon-active accordion-plus\"><i class=\"fa fa-chevron-down\"><\/i><\/span>\r\n                        <span class=\"accordion-icon-inactive accordion-minus\"><i class=\"fa fa-chevron-up\"><\/i><\/span>\r\n                    <\/span>\r\n                    <span id=\"header-text-1726481344806\" class=\"accordions-head-title\">What is surge protection?<\/span>\r\n                            <\/div>\r\n            <div class=\"accordion-content content1726481344806 \">\r\n                <p>Overvoltage protection is the protection of electrical and electronic devices against excessive electrical voltages. There are various ways in which an overvoltage can occur: through lightning or through capacitive or inductive coupling from other electrical systems. Effective protection also includes external lightning protection, which protects against lightning strikes in the vicinity of electrical systems.<\/p>\n<p>To ensure reliable surge protection, you can rely on ZORC modules from GINO. These protection devices are specially developed to dissipate overvoltages and thus protect systems from damage. They switch quickly in the event of overvoltages and conduct the current safely to earth to protect devices and systems.<\/p>\n            <\/div>\r\n    \r\n            <div post_id=\"10209\" itemcount=\"1\"  header_id=\"header-1726481385656\" id=\"header-1726481385656\" style=\"\" class=\"accordions-head head1726481385656 border-none\" toggle-text=\"\" main-text=\"What consequences can an overvoltage have?\">\r\n                                    <span id=\"accordion-icons-1726481385656\" class=\"accordion-icons\">\r\n                        <span class=\"accordion-icon-active accordion-plus\"><i class=\"fa fa-chevron-down\"><\/i><\/span>\r\n                        <span class=\"accordion-icon-inactive accordion-minus\"><i class=\"fa fa-chevron-up\"><\/i><\/span>\r\n                    <\/span>\r\n                    <span id=\"header-text-1726481385656\" class=\"accordions-head-title\">What consequences can an overvoltage have?<\/span>\r\n                            <\/div>\r\n            <div class=\"accordion-content content1726481385656 \">\r\n                <p>Overvoltages can have a considerable impact in industry. If they are not properly discharged or protected, they can cause serious damage to electrical systems and devices. Surge protection devices play a crucial role in protecting sensitive electronic equipment from the dangers of external overvoltage.<\/p>\n<p>Without adequate protection, overvoltages in industry can have serious consequences. They can destroy electrical systems and devices in a short space of time, from damage to motors and generators to breakdowns in production processes. The use of suitable surge protection devices and external lightning protection is therefore of great importance. Effective protection ensures that the operating environment is reliably protected, employees can work safely and production downtimes are minimized.<\/p>\n            <\/div>\r\n    <\/div>\r\n\r\n\r\n\r\n            <\/div><\/div><div id=\"panel-3324-0-0-4\" class=\"so-panel widget widget_siteorigin-panels-builder\" data-index=\"4\" ><div id=\"pl-w6645ad959cc2b\"  class=\"panel-layout\" ><div id=\"pg-w6645ad959cc2b-0\"  class=\"panel-grid panel-no-style\" ><div id=\"pgc-w6645ad959cc2b-0-0\"  class=\"panel-grid-cell\" ><div id=\"panel-w6645ad959cc2b-0-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\" data-index=\"0\" ><div class=\"panel-widget-style panel-widget-style-for-w6645ad959cc2b-0-0-0\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-editor so-widget-sow-editor-base\"\n\t\t\t\n\t\t>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<h3 aria-level=\"2\">Product functions<\/h3>\n<ul>\n<li aria-level=\"2\">System voltage: 400 V to 40 kV<\/li>\n<li aria-level=\"2\">Protection against interference factors: In the range of 0.1 to 0.2 microseconds<\/li>\n<li aria-level=\"2\">Particularly compact models can be installed in almost all connection housings of motors and transformers or switchgear<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\" img-responsive alignnone\" src=\"https:\/\/www.gino-ag.com\/wp-content\/uploads\/Verschaltung.png\" alt=\"\u00dcberspannungsschutz Abbildung ZORC Modul\" width=\"392\" height=\"285\" \/><\/p>\n<\/div>\n<\/div><\/div><\/div><\/div><div id=\"pgc-w6645ad959cc2b-0-1\"  class=\"panel-grid-cell\" ><div id=\"panel-w6645ad959cc2b-0-1-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\" data-index=\"1\" ><div class=\"panel-widget-style panel-widget-style-for-w6645ad959cc2b-0-1-0\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-editor so-widget-sow-editor-base\"\n\t\t\t\n\t\t>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<h3>Installing the surge arrester<\/h3>\n<p>The ZORC surge arrester can be installed on the side of the machine in any orientation, even overhead. The following must be observed when wiring:<\/p>\n<ul>\n<li>A ZORC module is connected to each phase and earthed in the terminal box of the motor, generator or transformer.<\/li>\n<li>The wiring to the terminal box is made with a three-core cable (min. 25 mm\u00b2) and a protective earth conductor.<\/li>\n<li>The ZORC module can also be connected in series with the connection cable and in parallel from each phase to earth.<\/li>\n<li>Suitable brackets or connections are supplied.<\/li>\n<\/ul>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><div id=\"panel-3324-0-0-5\" class=\"so-panel widget widget_siteorigin-panels-builder\" data-index=\"5\" ><div id=\"pl-w6645ad959da9f\"  class=\"panel-layout\" ><div id=\"pg-w6645ad959da9f-0\"  class=\"panel-grid panel-no-style\" ><div id=\"pgc-w6645ad959da9f-0-0\"  class=\"panel-grid-cell\" ><div id=\"panel-w6645ad959da9f-0-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\" data-index=\"0\" ><div class=\"panel-widget-style panel-widget-style-for-w6645ad959da9f-0-0-0\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-editor so-widget-sow-editor-base\"\n\t\t\t\n\t\t>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<h3>Areas of application for surge arresters<\/h3>\n<ul>\n<li>Ventilation systems and fans<\/li>\n<li>pumps<\/li>\n<li>Motors and generators<\/li>\n<li>Crushers (shredders)<\/li>\n<li>generators<\/li>\n<li>Transport and conveyor belts<\/li>\n<li>compressors<\/li>\n<li>Induction and blast furnaces<\/li>\n<li>Auxiliary power plant equipment<\/li>\n<li>Freezing and cooling units<\/li>\n<li>Industrial mills<\/li>\n<li>Dry transformers<\/li>\n<li>Mini and mobile substations<\/li>\n<li>Mine winches<\/li>\n<\/ul>\n<\/div>\n<\/div><\/div><\/div><\/div><div id=\"pgc-w6645ad959da9f-0-1\"  class=\"panel-grid-cell\" ><div id=\"panel-w6645ad959da9f-0-1-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\" data-index=\"1\" ><div class=\"panel-widget-style panel-widget-style-for-w6645ad959da9f-0-1-0\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-editor so-widget-sow-editor-base\"\n\t\t\t\n\t\t>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<h3>General dimensions and reference values<\/h3>\n<p>The ZORC surge protection is a unique voltage and frequency dependent, closed cable network consisting of capacitors, resistors and non-linear zinc oxide arresters.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\" img-responsive alignnone wp-image-3342\" style=\"font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; font-family: 'Open Sans Condensed', sans-serif; font-size: 16px; letter-spacing: 0.64px;\" src=\"https:\/\/www.gino-ag.com\/wp-content\/uploads\/ZinkOxidAbleiter.png\" alt=\"ZORC-\u00dcberspannungsschutz Abbildung\" width=\"391\" height=\"200\" srcset=\"https:\/\/www.gino-ag.com\/wp-content\/uploads\/ZinkOxidAbleiter.png 552w, https:\/\/www.gino-ag.com\/wp-content\/uploads\/ZinkOxidAbleiter-320x163.png 320w\" sizes=\"auto, (max-width: 391px) 100vw, 391px\" \/><\/p>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><div id=\"panel-3324-0-0-6\" class=\"so-panel widget widget_text\" data-index=\"6\" >\t\t\t<div class=\"textwidget\"><p>\n<table id=\"tablepress-1\" class=\"tablepress tablepress-id-1 tbody-has-connected-cells\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Standard: 3 Phase<\/th><th class=\"column-2\">Typ<\/th><th class=\"column-3\">Breite [mm]<\/th><th class=\"column-4\">H\u00f6he [mm]<\/th><th class=\"column-5\">Tiefe [mm]<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"row-2\">\n\t<td rowspan=\"6\" class=\"column-1\"><img loading=\"lazy\" decoding=\"async\" width=\"100\" height=\"133\" src=\"https:\/\/www.gino-ag.com\/wp-content\/uploads\/635A2216_200.jpg\" alt=\"\" class=\"alignnone size-full wp-image-3436 img-responsive\" style=\"width: 100px;\" srcset=\"https:\/\/www.gino-ag.com\/wp-content\/uploads\/635A2216_200.jpg 200w, https:\/\/www.gino-ag.com\/wp-content\/uploads\/635A2216_200-128x170.jpg 128w\" sizes=\"auto, (max-width: 100px) 100vw, 100px\" \/><\/td><td class=\"column-2\">M3 - 3 kV<\/td><td class=\"column-3\">428<\/td><td class=\"column-4\">444<\/td><td class=\"column-5\">138<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-2\">M3 - 4,16 kV<\/td><td class=\"column-3\">428<\/td><td class=\"column-4\">444<\/td><td class=\"column-5\">138<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-2\">M3 - 6 kV<\/td><td class=\"column-3\">428<\/td><td class=\"column-4\">444<\/td><td class=\"column-5\">138<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-2\">M3 - 7,2 kV<\/td><td class=\"column-3\">428<\/td><td class=\"column-4\">444<\/td><td class=\"column-5\">138<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-2\">M3 - 11 kV<\/td><td class=\"column-3\">535<\/td><td class=\"column-4\">489<\/td><td class=\"column-5\">105<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-2\">M3 - 12 kV\/13 kV<\/td><td class=\"column-3\">535<\/td><td class=\"column-4\">489<\/td><td class=\"column-5\">120<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-1 from cache --><br \/>\n\n<table id=\"tablepress-2\" class=\"tablepress tablepress-id-2 tbody-has-connected-cells\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Kompakt: 3 Phase<\/th><th class=\"column-2\">Typ<\/th><th class=\"column-3\">Breite [mm]<\/th><th class=\"column-4\">H\u00f6he [mm]<\/th><th class=\"column-5\">Tiefe [mm]<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"row-2\">\n\t<td rowspan=\"3\" class=\"column-1\"><img loading=\"lazy\" decoding=\"async\" width=\"100\" height=\"93\" src=\"https:\/\/www.gino-ag.com\/wp-content\/uploads\/635A2205_200.jpg\" alt=\"\" class=\"alignnone size-full wp-image-3435 img-responsive\" style=\"width: 100px;\" srcset=\"https:\/\/www.gino-ag.com\/wp-content\/uploads\/635A2205_200.jpg 200w, https:\/\/www.gino-ag.com\/wp-content\/uploads\/635A2205_200-183x170.jpg 183w\" sizes=\"auto, (max-width: 100px) 100vw, 100px\" \/><\/td><td class=\"column-2\">M3C - 3 kV<\/td><td class=\"column-3\">280<\/td><td class=\"column-4\">242<\/td><td class=\"column-5\">116<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-2\">M3C - 4,16 kV<\/td><td class=\"column-3\">280<\/td><td class=\"column-4\">242<\/td><td class=\"column-5\">116<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-2\">M3C - 6 kV<\/td><td class=\"column-3\">280<\/td><td class=\"column-4\">242<\/td><td class=\"column-5\">116<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-2 from cache --><br \/>\n\n<table id=\"tablepress-3\" class=\"tablepress tablepress-id-3 tbody-has-connected-cells\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Niederspannung: 3 Phase<\/th><th class=\"column-2\">Typ<\/th><th class=\"column-3\">Breite [mm]<\/th><th class=\"column-4\">H\u00f6he [mm]<\/th><th class=\"column-5\">Tiefe [mm]<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"row-2\">\n\t<td rowspan=\"4\" class=\"column-1\"><img loading=\"lazy\" decoding=\"async\" width=\"100\" height=\"119\" src=\"https:\/\/www.gino-ag.com\/wp-content\/uploads\/LVZ-no-logo_200.jpg\" alt=\"\" class=\"alignnone size-full wp-image-3437 img-responsive\" style=\"width: 100px;\" srcset=\"https:\/\/www.gino-ag.com\/wp-content\/uploads\/LVZ-no-logo_200.jpg 200w, https:\/\/www.gino-ag.com\/wp-content\/uploads\/LVZ-no-logo_200-143x170.jpg 143w\" sizes=\"auto, (max-width: 100px) 100vw, 100px\" \/><\/td><td class=\"column-2\">LVZ400<\/td><td class=\"column-3\">182<\/td><td class=\"column-4\">255<\/td><td class=\"column-5\">90<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-2\">LVZ550<\/td><td class=\"column-3\">182<\/td><td class=\"column-4\">255<\/td><td class=\"column-5\">90<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-2\">LVZ690<\/td><td class=\"column-3\">182<\/td><td class=\"column-4\">255<\/td><td class=\"column-5\">90<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-2\">LVZ1000<\/td><td class=\"column-3\">182<\/td><td class=\"column-4\">255<\/td><td class=\"column-5\">90<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-3 from cache --><br \/>\n\n<table id=\"tablepress-4\" class=\"tablepress tablepress-id-4 tbody-has-connected-cells\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">RC Entst\u00f6rglied: 1 Phase<\/th><th class=\"column-2\">Typ<\/th><th class=\"column-3\">Breite [mm]<\/th><th class=\"column-4\">H\u00f6he [mm]<\/th><th class=\"column-5\">Tiefe [mm]<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"row-2\">\n\t<td rowspan=\"5\" class=\"column-1\"><img loading=\"lazy\" decoding=\"async\" width=\"100\" height=\"158\" src=\"https:\/\/www.gino-ag.com\/wp-content\/uploads\/RCSurgesuppressorAssembly_200.jpg\" alt=\"\" class=\"alignnone size-full wp-image-3438 img-responsive\" style=\"width: 100px;\" srcset=\"https:\/\/www.gino-ag.com\/wp-content\/uploads\/RCSurgesuppressorAssembly_200.jpg 200w, https:\/\/www.gino-ag.com\/wp-content\/uploads\/RCSurgesuppressorAssembly_200-108x170.jpg 108w\" sizes=\"auto, (max-width: 100px) 100vw, 100px\" \/><\/td><td class=\"column-2\">M1 - 22 kV<\/td><td class=\"column-3\">343<\/td><td class=\"column-4\">655<\/td><td class=\"column-5\">117<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-2\">M1 - 25 kV<\/td><td class=\"column-3\">433<\/td><td class=\"column-4\">1516<\/td><td class=\"column-5\">414<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-2\">M1 - 33 kV<\/td><td class=\"column-3\">433<\/td><td class=\"column-4\">1310<\/td><td class=\"column-5\">433<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-2\">M1 - 36 kV<\/td><td class=\"column-3\">433<\/td><td class=\"column-4\">1310<\/td><td class=\"column-5\">433<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-2\">M1 - 40 kV<\/td><td class=\"column-3\">433<\/td><td class=\"column-4\">1310<\/td><td class=\"column-5\">433<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-4 from cache --><\/p>\n<\/div>\n\t\t<\/div><div id=\"panel-3324-0-0-7\" class=\"so-panel widget widget_block panel-last-child\" data-index=\"7\" ><div style=\"background-color: white; border: 4px solid yellow; border-radius: 10px; padding: 20px;\">\n<h3 style=\"margin-bottom: 10px;\">Do you have any questions?<\/h3>\n<p style=\"margin-bottom: 20px;\">Click through our brochure on surge protection with system or contact us directly. We look forward to hearing from you.<\/p>\n<div style=\"display: flex; align-items: center;\">\n    <a href=\"https:\/\/www.gino-ag.com\/wp-content\/uploads\/GINO-Katalog_ZORC_Rev-E_de-1.pdf\" style=\"background-color: #b0b0b0; color: black; padding: 10px 20px; text-decoration: none; border-radius: 5px; margin-right: 10px;\">Prospect<\/a><br \/>\n    <a href=\"https:\/\/www.gino-ag.com\/de\/kontakt\/kontakt\/\" style=\"background-color: black; color: white; padding: 10px 20px; text-decoration: none; border-radius: 5px;\">Contact us<\/a>\n  <\/div>\n<\/div>\n<\/div><\/div><div id=\"pgc-3324-0-1\"  class=\"panel-grid-cell\" ><div id=\"panel-3324-0-1-0\" class=\"so-panel widget widget_black-studio-tinymce widget_black_studio_tinymce panel-first-child\" data-index=\"8\" ><div class=\"info-box panel-widget-style panel-widget-style-for-3324-0-1-0\" ><div class=\"textwidget\"><div class=\"info-box\">\n<h2>Contact person<\/h2>\n<p>David Jansen<br \/>\nPhone: +49 (0) 228 98986-935<br \/>\nEmail: <a href=\"mailto:david.jansen@gino.de\">david.jansen@gino.de<\/a><\/div>\n<\/div><\/div><\/div><div id=\"panel-3324-0-1-1\" class=\"so-panel widget widget_nav_menu\" data-index=\"9\" ><div class=\"sidebar panel-widget-style panel-widget-style-for-3324-0-1-1\" ><div class=\"menu-submenu-products-en-container\"><ul id=\"menu-submenu-products-en\" class=\"menu\"><li id=\"menu-item-8018\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8018\"><a href=\"https:\/\/gino-ag.xtek.site\/en\/products\/resistance-systems-gino-ag\/\" title=\"Resistor systems\"><i>Overview Resistor systems<\/i><\/a><\/li>\n<li id=\"menu-item-8010\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-has-children menu-item-8010\"><a href=\"https:\/\/gino-ag.xtek.site\/en\/products\/load-and-test-resistors\/\">Load and test resistors<\/a>\n<ul class=\"sub-menu\">\n\t<li id=\"menu-item-8014\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8014\"><a href=\"https:\/\/gino-ag.xtek.site\/en\/products\/load-and-test-resistors\/standard-power-banks\/\">Standard load banks<\/a><\/li>\n\t<li id=\"menu-item-8011\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8011\"><a href=\"https:\/\/gino-ag.xtek.site\/en\/products\/load-and-test-resistors\/customer-specific-load-banks\/\">Customer specific load banks<\/a><\/li>\n\t<li id=\"menu-item-8013\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8013\"><a href=\"https:\/\/gino-ag.xtek.site\/en\/products\/load-and-test-resistors\/mobile-load-banks-on-trailers\/\">Mobile load banks on trailers<\/a><\/li>\n\t<li id=\"menu-item-8015\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8015\"><a href=\"https:\/\/gino-ag.xtek.site\/en\/products\/load-and-test-resistors\/test-resistors\/\">Test resistors<\/a><\/li>\n\t<li id=\"menu-item-8012\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8012\"><a href=\"https:\/\/gino-ag.xtek.site\/en\/products\/load-and-test-resistors\/load-banks-for-locomotives\/\">Load banks for locomotives<\/a><\/li>\n<\/ul>\n<\/li>\n<li id=\"menu-item-7998\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-7998\"><a href=\"https:\/\/gino-ag.xtek.site\/en\/products\/brake-resistors\/\">Braking resistors<\/a><\/li>\n<li id=\"menu-item-8008\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8008\"><a href=\"https:\/\/gino-ag.xtek.site\/en\/products\/grounding-resistors-gino-ag\/\">Earthing resistors<\/a><\/li>\n<li id=\"menu-item-8004\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8004\"><a href=\"https:\/\/gino-ag.xtek.site\/en\/products\/damping-resistors\/\">Damping resistors<\/a><\/li>\n<li id=\"menu-item-8019\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8019\"><a href=\"https:\/\/gino-ag.xtek.site\/en\/products\/transportation-engineering-train-resistors\/\">Transportation engineering \/ train resistors<\/a><\/li>\n<li id=\"menu-item-10124\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-10124\"><a href=\"https:\/\/gino-ag.xtek.site\/en\/products\/girdbox\/\">Gridbox<\/a><\/li>\n<li id=\"menu-item-8017\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8017\"><a href=\"https:\/\/gino-ag.xtek.site\/en\/products\/discover-oil-starter-now-gino-ag\/\">Oil-cooled resistor starters<\/a><\/li>\n<li id=\"menu-item-8006\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8006\"><a href=\"https:\/\/gino-ag.xtek.site\/en\/products\/akamas-gino-ag\/\">GINO-AKA AKAMAS<\/a><\/li>\n<li id=\"menu-item-8007\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8007\"><a href=\"https:\/\/gino-ag.xtek.site\/en\/products\/power-controller-gino-ag\/\">GINO-AKA power controllers<\/a><\/li>\n<li id=\"menu-item-8009\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8009\"><a href=\"https:\/\/gino-ag.xtek.site\/en\/products\/discover-liquid-starters-gino-ag\/\">Liquid cooled starters<\/a><\/li>\n<li id=\"menu-item-8016\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8016\"><a href=\"https:\/\/gino-ag.xtek.site\/en\/products\/discover-air-cooled-starter-gino-ag\/\">Air cooled motor starters<\/a><\/li>\n<li id=\"menu-item-8020\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8020\"><a href=\"https:\/\/gino-ag.xtek.site\/en\/products\/discover-surge-protection-gino-ag\/\">Surge suppressor<\/a><\/li>\n<li id=\"menu-item-8005\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8005\"><a href=\"https:\/\/gino-ag.xtek.site\/en\/products\/cooling-systems-gino-ag\/\">Fans \/ cooling systems<\/a><\/li>\n<li id=\"menu-item-7999\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-has-children menu-item-7999\"><a href=\"https:\/\/gino-ag.xtek.site\/en\/products\/electric-contactors-gino-ag\/\">Contactors<\/a>\n<ul class=\"sub-menu\">\n\t<li id=\"menu-item-8000\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8000\"><a href=\"https:\/\/gino-ag.xtek.site\/en\/products\/electric-contactors-gino-ag\/contactors-hb-series\/\">Contactors \u2013 HB series<\/a><\/li>\n\t<li id=\"menu-item-8003\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8003\"><a href=\"https:\/\/gino-ag.xtek.site\/en\/products\/electric-contactors-gino-ag\/contactors-t-series\/\">Contactors \u2013 T series<\/a><\/li>\n\t<li id=\"menu-item-8001\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8001\"><a href=\"https:\/\/gino-ag.xtek.site\/en\/products\/electric-contactors-gino-ag\/contactors-r-series\/\">Contactors \u2013 R series<\/a><\/li>\n\t<li id=\"menu-item-8002\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8002\"><a href=\"https:\/\/gino-ag.xtek.site\/en\/products\/electric-contactors-gino-ag\/contactors-s-series\/\">Contactors \u2013 S-Series<\/a><\/li>\n<\/ul>\n<\/li>\n<\/ul><\/div><\/div><\/div><div id=\"panel-3324-0-1-2\" class=\"so-panel widget widget_black-studio-tinymce widget_black_studio_tinymce panel-last-child\" data-index=\"10\" ><div class=\"info-box panel-widget-style panel-widget-style-for-3324-0-1-2\" ><div class=\"textwidget\"><div class=\"info-box\">\n<h2>DOWNLOADS<\/h2>\n<ul>\n<li><a href=\"https:\/\/www.gino-ag.com\/wp-content\/uploads\/GINO-AG_Catalog_Surge-suppressor_en-1.pdf\" target=\"_blank\" rel=\"noopener\">Prospect Surge Suppressor<\/a> (PDF)<\/li>\n<\/ul>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Transient overvoltage protection with ZORC modules GINO AG is the exclusive distributor of ZORC modules in Germany. With the modules, we guarantee you safe surge protection. Protect your valuable electronic equipment with our ZORC modules for surge protection. Contact us today for more information and to find the optimal solution for your individual needs. Rely [&hellip;]<\/p>\n","protected":false},"author":19,"featured_media":5768,"parent":954,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-3324","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>\u00dcberspannungsschutz entdecken | GINO AG<\/title>\n<meta name=\"description\" content=\"\u00dcberspannungsschutz f\u00fcr Motoren, Transformatoren &amp; Generatoren \u2705 Schutz vor Spannungsspitzen &amp; St\u00f6rfaktoren \u25ba jetzt entdecken\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/gino-ag.xtek.site\/en\/products\/discover-surge-protection-gino-ag\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u00dcberspannungsschutz entdecken | GINO AG\" \/>\n<meta property=\"og:description\" content=\"\u00dcberspannungsschutz f\u00fcr Motoren, Transformatoren &amp; Generatoren \u2705 Schutz vor Spannungsspitzen &amp; St\u00f6rfaktoren \u25ba jetzt entdecken\" \/>\n<meta property=\"og:url\" content=\"https:\/\/gino-ag.xtek.site\/en\/products\/discover-surge-protection-gino-ag\/\" \/>\n<meta property=\"og:site_name\" content=\"GINO AG\" \/>\n<meta property=\"article:modified_time\" content=\"2025-02-04T13:39:38+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.gino-ag.com\/wp-content\/uploads\/GINO_Produkte_Ueberspannungsschutz.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"480\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/gino-ag.xtek.site\/en\/products\/discover-surge-protection-gino-ag\/\",\"url\":\"https:\/\/gino-ag.xtek.site\/en\/products\/discover-surge-protection-gino-ag\/\",\"name\":\"\u00dcberspannungsschutz entdecken | GINO AG\",\"isPartOf\":{\"@id\":\"https:\/\/www.gino-ag.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/gino-ag.xtek.site\/en\/products\/discover-surge-protection-gino-ag\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/gino-ag.xtek.site\/en\/products\/discover-surge-protection-gino-ag\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.gino-ag.com\/wp-content\/uploads\/GINO_Produkte_Ueberspannungsschutz.jpg\",\"datePublished\":\"2019-06-03T11:46:47+00:00\",\"dateModified\":\"2025-02-04T13:39:38+00:00\",\"description\":\"\u00dcberspannungsschutz f\u00fcr Motoren, Transformatoren & Generatoren \u2705 Schutz vor Spannungsspitzen & St\u00f6rfaktoren \u25ba jetzt entdecken\",\"breadcrumb\":{\"@id\":\"https:\/\/gino-ag.xtek.site\/en\/products\/discover-surge-protection-gino-ag\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/gino-ag.xtek.site\/en\/products\/discover-surge-protection-gino-ag\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/gino-ag.xtek.site\/en\/products\/discover-surge-protection-gino-ag\/#primaryimage\",\"url\":\"https:\/\/www.gino-ag.com\/wp-content\/uploads\/GINO_Produkte_Ueberspannungsschutz.jpg\",\"contentUrl\":\"https:\/\/www.gino-ag.com\/wp-content\/uploads\/GINO_Produkte_Ueberspannungsschutz.jpg\",\"width\":1920,\"height\":480},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/gino-ag.xtek.site\/en\/products\/discover-surge-protection-gino-ag\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\/\/www.gino-ag.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/www.gino-ag.com\/en\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Surge suppressor\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.gino-ag.com\/en\/#website\",\"url\":\"https:\/\/www.gino-ag.com\/en\/\",\"name\":\"GINO AG\",\"description\":\"Elektrische Widerst\u00e4nde von 50 W bis 360 MW\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.gino-ag.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u00dcberspannungsschutz entdecken | GINO AG","description":"\u00dcberspannungsschutz f\u00fcr Motoren, Transformatoren & Generatoren \u2705 Schutz vor Spannungsspitzen & St\u00f6rfaktoren \u25ba jetzt entdecken","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/gino-ag.xtek.site\/en\/products\/discover-surge-protection-gino-ag\/","og_locale":"en_US","og_type":"article","og_title":"\u00dcberspannungsschutz entdecken | GINO AG","og_description":"\u00dcberspannungsschutz f\u00fcr Motoren, Transformatoren & Generatoren \u2705 Schutz vor Spannungsspitzen & St\u00f6rfaktoren \u25ba jetzt entdecken","og_url":"https:\/\/gino-ag.xtek.site\/en\/products\/discover-surge-protection-gino-ag\/","og_site_name":"GINO AG","article_modified_time":"2025-02-04T13:39:38+00:00","og_image":[{"width":1920,"height":480,"url":"https:\/\/www.gino-ag.com\/wp-content\/uploads\/GINO_Produkte_Ueberspannungsschutz.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/gino-ag.xtek.site\/en\/products\/discover-surge-protection-gino-ag\/","url":"https:\/\/gino-ag.xtek.site\/en\/products\/discover-surge-protection-gino-ag\/","name":"\u00dcberspannungsschutz entdecken | GINO AG","isPartOf":{"@id":"https:\/\/www.gino-ag.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/gino-ag.xtek.site\/en\/products\/discover-surge-protection-gino-ag\/#primaryimage"},"image":{"@id":"https:\/\/gino-ag.xtek.site\/en\/products\/discover-surge-protection-gino-ag\/#primaryimage"},"thumbnailUrl":"https:\/\/www.gino-ag.com\/wp-content\/uploads\/GINO_Produkte_Ueberspannungsschutz.jpg","datePublished":"2019-06-03T11:46:47+00:00","dateModified":"2025-02-04T13:39:38+00:00","description":"\u00dcberspannungsschutz f\u00fcr Motoren, Transformatoren & Generatoren \u2705 Schutz vor Spannungsspitzen & St\u00f6rfaktoren \u25ba jetzt entdecken","breadcrumb":{"@id":"https:\/\/gino-ag.xtek.site\/en\/products\/discover-surge-protection-gino-ag\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/gino-ag.xtek.site\/en\/products\/discover-surge-protection-gino-ag\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/gino-ag.xtek.site\/en\/products\/discover-surge-protection-gino-ag\/#primaryimage","url":"https:\/\/www.gino-ag.com\/wp-content\/uploads\/GINO_Produkte_Ueberspannungsschutz.jpg","contentUrl":"https:\/\/www.gino-ag.com\/wp-content\/uploads\/GINO_Produkte_Ueberspannungsschutz.jpg","width":1920,"height":480},{"@type":"BreadcrumbList","@id":"https:\/\/gino-ag.xtek.site\/en\/products\/discover-surge-protection-gino-ag\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/www.gino-ag.com\/en\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/www.gino-ag.com\/en\/products\/"},{"@type":"ListItem","position":3,"name":"Surge suppressor"}]},{"@type":"WebSite","@id":"https:\/\/www.gino-ag.com\/en\/#website","url":"https:\/\/www.gino-ag.com\/en\/","name":"GINO AG","description":"Elektrische Widerst\u00e4nde von 50 W bis 360 MW","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.gino-ag.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/gino-ag.xtek.site\/en\/wp-json\/wp\/v2\/pages\/3324","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gino-ag.xtek.site\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/gino-ag.xtek.site\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/gino-ag.xtek.site\/en\/wp-json\/wp\/v2\/users\/19"}],"replies":[{"embeddable":true,"href":"https:\/\/gino-ag.xtek.site\/en\/wp-json\/wp\/v2\/comments?post=3324"}],"version-history":[{"count":18,"href":"https:\/\/gino-ag.xtek.site\/en\/wp-json\/wp\/v2\/pages\/3324\/revisions"}],"predecessor-version":[{"id":10282,"href":"https:\/\/gino-ag.xtek.site\/en\/wp-json\/wp\/v2\/pages\/3324\/revisions\/10282"}],"up":[{"embeddable":true,"href":"https:\/\/gino-ag.xtek.site\/en\/wp-json\/wp\/v2\/pages\/954"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gino-ag.xtek.site\/en\/wp-json\/wp\/v2\/media\/5768"}],"wp:attachment":[{"href":"https:\/\/gino-ag.xtek.site\/en\/wp-json\/wp\/v2\/media?parent=3324"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}